TMS RF · ANDROID · v1.3.1

TMS RF for Android: features and operation

A tour of the Android app for the station: pairing sensors, the four measurement modes, batch jobs, records and export, Modbus TCP and fault alerts. Screens are from the product.

ANDROID 8.0+, 64-BIT ARM RF 2.4G RECEIVER, USB-OTG 191-PAGE MANUAL

What TMS RF is and how it fits together

TMS RF is an Android app that receives torque and angle data from RF 2.4G sensors, judges each tightening OK or NOK, and saves every record with its curve.

ZIPPTORK TMS runs on an Android tablet or phone; the home screen shows “TMS RF”. This page follows version 1.3.1. An RF 2.4G receiver on the USB-OTG port brings in data from a torque wrench, power tool or angle torque sensor. The app exports CSV or Excel and can feed a PLC over Modbus TCP.

Safety. TMS measures, judges and records. It does not control the tool or cut off its power.

The main menu has six functions: System Settings, Torque Wrench, Power Tool, Torque Measurement, Torque & Angle and Batch Jobs.

The main menu, titled Torque Monitoring System, with six large tiles in two rows of three.
Each tile opens one function. A work mode opens its parameter screen first; System Settings opens a menu of six administration screens.

Architecture

Sensor, then receiver (RF 2.4G), then the Android device running TMS (USB OTG), then optionally a PLC (Modbus TCP). A lit receiver only means USB power is present; trust the TMS screen status.

New in 1.3.1 compared with 1.1.11

  • A work screen with left and right areas, larger OK/NOK text and a progress band.
  • A “Data Curve” button for NOK results; smoother curves in record details.
  • A blank Target Torque after a sensor change, with the allowed range shown while editing.
  • A confirmation before a sensor is deleted, a pop-up list for “Tolerance Type”, and clearer login, user and record messages.

The work screen no longer shows a live curve. Measurement, judgement, export and Modbus behavior are unchanged, except for the TTAS angle torque sensor: an invalid angle reading as you ease off no longer interrupts the measurement, and if the angle signal is lost and torque is applied again, that cycle is saved as NOK. Real-device acceptance is incomplete, per the manual; test with your own equipment.

Device requirements

TMS needs a 64-bit ARM Android 8.0 or later device with USB host (OTG) support, used in landscape.

ItemMinimumRecommended tablet
Android8.0 (API 26)13 or later
Processor64-bit ARM (arm64-v8a)64-bit, 8 cores, 2.0 GHz class
WebViewAndroid System WebView 107Same
Free storage1 GB4 GB
MemoryNot stated4 GB (6 GB for long use)
ScreenLandscape, at least 320 × 360 CSS pixels8 inches, 1280×800

A USB-C port does not guarantee OTG; check the device. A phone suits auxiliary use (Android 13, 4 GB memory, 6 inches or larger). The layout adapts automatically: below 320 × 360 you see only “Make the window larger.”; a narrow window such as split screen gets a stacked layout, so avoid split screen while measuring.

Peripherals: one approved RF 2.4G USB receiver, a good OTG adapter, a charged sensor within its calibration period, and optionally a keyboard-mode (HID) barcode scanner and a Modbus TCP client on the same LAN.

Installing, updating and removing

Install the release APK on the device or push it with ADB, then confirm the version on the login screen.

Get the APK from the supplier (ZIPPTORK-TMS-RF-1.3.1-arm64-release.apk) and check it against the SHA-256 in the manual; earlier APKs shared the label 1.0.0, so the label alone proves nothing. Never use a Debug or test APK.

On the device

  1. Copy the APK to the device and tap it in Files.
  2. If blocked, turn on “Allow from this source”.
  3. Tap “Install” (or “Update”); at a Play Protect prompt choose “Install anyway” once you trust the file.
  4. Tap “Open”, then turn “Allow from this source” off.

With ADB (administrators)

  1. Enable “USB debugging” in Developer options.
  2. Run adb devices -l; the status must be device.
  3. Run adb install -r ZIPPTORK-TMS-RF-1.3.1-arm64-release.apk; Success means done.

If ADB reports INSTALL_FAILED_UPDATE_INCOMPATIBLE (different signing certificate), do not uninstall; export the data and ask the supplier.

First launch

Allow notifications (Android 13+) for sensor alerts, and USB access for the receiver; if denied, the screen shows “USB permission denied”, so re-plug the receiver. Allow the camera only to scan barcodes.

Updating

End the measurement, pause PLC polling and export a backup. Install over the existing app; users, pairings, parameters and records are kept. Confirm “v1.3.1” on the login screen and measure a test part. CSV and Excel files are not a restorable backup, and no verified restore procedure exists.

Warning. Uninstalling TMS, or using “Clear data” or “Clear storage” in Android settings, permanently deletes all local users, pairings, parameters and measurement records. Export the records first.

Completion checklist

  • The login screen shows “Version: v1.3.1” and “Build date: 11/23/2026”.
  • Sensor Pairing shows “Dongle connected” or “Paired”, and a test part gives a result.

Login, language, display and units

Log in with the default admin account, change its password at once, then set language, display mode and units.

On first launch with no users, TMS creates the account admin (password admin) with all permissions. Long-press “Log In” for about 0.6 seconds to fill in admin / admin, then tap it again. Change the password under System Settings → User Management → “Change Password”, then create separate accounts.

A wrong password, wrong username or disabled account all show “Incorrect username or password”. There is no “Log Out” button: to change user, close TMS from Recent apps and reopen it.

TMS has 16 interface languages, including English, Traditional and Simplified Chinese, Japanese, Korean, German, French and Arabic. Change the language with the language button on the login screen or in Global Settings. The “☾” / “☀” button in the top bar switches light mode (default) and dark mode; the choice is remembered and changes only colors.

Global settings

Path: System Settings → Global Settings (permission “System settings”). Torque Unit: N·m, kgf·cm, kgf·m, ozf·in, lbf·in or lbf·ft. Force Unit: kN, N, lbf or kgf. Tap “Save & Apply”. Units change only the display, because the database stores N·m: 50 N·m shows as 509.9 kgf·cm or 36.88 lbf·ft.

Users and permissions

Each person gets an account with only the permissions they need, chosen from eight switches.

The User Management screen with a user-account drop-down, Account enabled, Change Password and Add user buttons, and a grid of eight permission tiles.
Each tile has an Allow or Do not allow button, and a tap saves at once. Here the admin account has all eight on.

Path: System Settings → User Management (permission “User management”). Tap “Add user”, enter a username and password, and tap “Create user”. A new account is enabled but has all 8 permissions off; select it in “User accounts” and tap the tiles to “Allow”.

  • Run measurement: work screens, Batch Jobs, and “Data Curve” for your own NOK.
  • Pair sensors: receiver, channel, pairing, switching and deleting sensors.
  • Work management: add, edit and delete batch jobs.
  • Parameter settings: save each mode’s parameters.
  • System settings: save Global and Communication Settings.
  • Measurement records: search records and open details.
  • Export CSV: export CSV and Excel (also needs Measurement records).
  • User management: manage accounts and permissions.

“Account enabled” toggles to “Account disabled”; that account cannot log in, even in an open session, and its past records are kept. The last account that can manage users cannot be disabled (“At least one admin must remain”). This version cannot delete accounts or reset another person’s password, so disable the account when someone leaves. “Change Password” affects only the logged-in account.

Sensor pairing and the receiver

Plug in the receiver, pair each sensor once, and switch between paired sensors from one list.

Path: System Settings → Sensor Pairing (permission “Pair sensors”), with the “Pairing console” on the left and the “Paired sensor overview” on the right.

The Sensor Pairing screen: Pairing console on the left with receiver status and channel, Paired sensor overview on the right listing three sensors.
This capture has no receiver plugged in, so the status reads “Dongle not detected” while channel 49 and the paired list remain. Each paired sensor shows model, torque specification, serial number, channel and last verified time.

Receiver status and channel

“Dongle not detected” means no receiver or poor USB contact: reconnect and tap “Detect wireless receiver again”. “Dongle connected” means usable but not yet paired; “Paired” means communication works. “Dongle fault” is a USB or RF error: re-plug and detect again.

The channel in use is the large number (default 49). Tap it and choose 3 to 62; the paired list is kept. When several TMS systems share a plant, use channels at least 3 apart, for example 49, 52 and 55.

Pairing and switching

  1. End all jobs, plug in the receiver, allow USB access, and wait for “Dongle connected”.
  2. Put the sensor in pairing mode and check its model, specification and serial number under “Sensor awaiting pairing”.
  3. Tap “Start sensor pairing” and wait for “Paired”; the sensor appears marked “In use”.
The All paired sensors pop-up listing three sensors with round selection buttons, Cancel at the top right, and Connect and use and Delete sensor at the bottom.
Select a sensor’s round button, then tap Connect and use; the receiver switches to that sensor’s channel. Delete sensor asks for confirmation first.

“View all sensors” opens the list. Warning. After you confirm “Unpair sensor”, the pairing is deleted at once and cannot be restored; check the serial number first. Saved records are not affected.

RF diagnostic capture

Only the admin account created at first launch sees “Diagnostic capture”. “Start capture” records receiver traffic (limit about 5 minutes or 2 MiB); “Finish and seal”, then “Export diagnostic file” for the supplier.

Work parameters and screens common to all modes

The four measurement modes share one parameter layout, one limit calculation and the same work-screen parts.

Torque Wrench Parameter Settings in three columns: Work Info, Target Torque and Parameter Settings, with a full-width button along the bottom.
Station and Part Number each have a camera icon for scanning. The long bottom button has no text; its name is “Save & Apply → Work”.

Common fields

FieldMeaningLimit or default
Tolerance %, Tolerance TypeAllowed deviation; “±” or “≥”.0 to below 100; default 10, “±”.
Batch Counting, OK count per batchShows “Batch Complete” at the count.Off; 1–999, default 1.
Multiplier, Torque Ratio, Gear RatioFor a torque multiplier.Off; ratios above 0.

“Select sensor” lists the paired sensors in a search pop-up. A different sensor clears Target Torque and sets the seating torque to 20% of the new specification. Tap the empty Target Torque field and the allowed range appears at the bottom: from 10% of the specification (5% for a 10 N·m sensor) up to the specification, times the torque ratio if the multiplier is on.

The upper limit is target × (1 + tolerance %). The lower limit is target × (1 − tolerance %) with “±”, and the target itself with “≥”. Example, target 50.00 N·m and 5%: “±” gives 47.50–52.50, so 48.72 is OK and 54.20 is NOK; “≥” gives 50.00–52.50, so 48.72 is NOK. With a multiplier, torque shown is sensor torque × torque ratio and angle is sensor angle ÷ gear ratio.

“Save & Apply → Work” validates, saves (permission “Parameter settings”), opens the work screen and starts measuring; there is no start button. A failure shows red “Failed to load or save settings”.

Barcode scanning

The camera icon beside Station and Part Number scans 1D and 2D barcodes; review the text, then tap “Apply”. Leading zeros are kept and no photos are saved. The manual says only limited real-device checking was done, so test a sample barcode first.

Work screen and result states

The work screen shows a status bar (Receiver, S/N, Model, Spec, Battery), the result card, a side card for mode-specific readings, OK/NOK statistics and a spec strip with the limits.

  • Pending: no complete apply-and-release cycle yet; Disconnected: link lost.
  • OK (green) and NOK (red): saved automatically; NOK is not counted toward the batch.
  • Conditions not met: no valid judgement and nothing counted; repeat the work.

A measurement starts only when torque reaches 10% of the sensor specification (5% for a 10 N·m sensor); lower readings are not judged, recorded or sent to the PLC. After OK the part number clears; after NOK it stays for rework. At the OK count, “Batch Complete” shows for about 1 second.

The progress band shows the current value (▲) against a gray zone below the lower limit, a green OK zone and a red zone above the upper limit. It is a visual aid only; the result comes from the judgement rules. Batch screens have none.

A “Sensor fault” banner shows at the top: yellow “Warning only” lets you continue, red “Work stopped” blocks work (see the fault section).

NOK diagnosis with “Data Curve”

The Torque / Time Curve window over a work screen: a blue torque line against time with dashed limit lines, a header with limits and data point count, and a Back button at the upper right.
The header lists the limits and the data point count (39 here). Tap the curve to read values, and look at where the line crosses the upper limit. Back closes the window.

After an NOK, a red-framed “Data Curve” button appears at the bottom. It opens a torque/time curve (Torque Wrench, Power Tool) or torque/angle curve (angle modes). It needs “Run measurement”, works only for the user who made the measurement and only while that NOK is on screen; afterwards use the record details.

Torque Wrench mode

Torque Wrench mode judges the peak torque of each apply-and-release cycle against the torque limits.

It suits manual torque wrenches such as TTES sensors. It has no target angle or seating torque.

The Torque Wrench work screen after an NOK: a red result card, Max Torque 3.54 N·m with the progress band pointer at the far right, and a red-framed Data Curve button at the lower right.
The result card is red and the pointer sits beyond the upper limit. The Data Curve button at the lower right opens the curve of this tightening.

“Live Torque” follows the applied torque; after the result it becomes “Max Torque” and holds the peak until the next force starts. Rule: OK if the peak is between the lower and upper limits.

Example: TTES 100 N·m, target 50 N·m, ±5% (47.50–52.50), batch of 5. Tighten to 49.00 N·m and release: green OK, Batch 1 / 5, part field cleared. Tighten to 54.20 N·m: red NOK, part number kept for rework.

Power Tool mode

Power Tool mode judges the peak torque of each cycle for pulse, impact and clutch tools, and shows pulse count and timing for reference.

“Tool Type” is “Pulse” (default), “Impact” or “Clutch”. “Detection Time” turns on a work-time reminder with a “Work Time” in seconds (not for Clutch). There is no multiplier setting.

The Power Tool work screen waiting for a part: Pending result, live torque 0.00 N·m with a torque progress band, and a side card listing Pulse Count, Time to peak torque, Tool Type, Work Time and Detection Time.
The side card on the right is specific to this mode. Its values are reference data; the result depends only on peak torque against the limits.

The side card shows Pulse Count (highest count while torque was above 0), Time to peak torque, Work Time (first torque until it returns to 0), Tool Type and Detection Time. Rule: OK if the peak torque is within the limits; work time and pulse count never turn a result into NOK.

Example: TTEB 10 N·m, impact tool, target 5.00 N·m ±5% (4.75–5.25). Result: Max Torque 4.98 N·m, OK, Pulse Count 25, Time to peak torque 11.98 s, Work Time 12.73 s.

Torque Measurement mode

Torque Measurement reads the torque at the moment the part has rotated to a target angle and judges that value.

It suits residual torque checks and needs an angle-output sensor such as TTAS. The judgement uses the angle-point torque, not the maximum torque.

Torque Measurement Parameter Settings in three columns: Work Info, Target Torque with Seating Torque, and Task Parameters with Target Angle, Batch Counting and multiplier fields.
Seating Torque sits in the Target Torque column and Target Angle in Task Parameters. Torque Wrench mode has neither.

Seating Torque starts the angle count when torque first reaches it (default 20% of the specification). Target Angle runs from 1° up to the smaller of 360° and 3276.7 ÷ gear ratio. Target Torque and tolerance set the range for the angle-point torque.

Apply force above the seating torque, rotate past the target angle and release. “Angle-point Torque” then appears on the side card and decides OK/NOK; the main reading shows “Max Torque” for reference. TMS interpolates between the nearest data points: for a 5° target with 4° at 20 N·m and 6° at 24 N·m, the result is 22 N·m.

“Conditions not met” appears when the seating torque was not reached, the rotation did not pass the target angle, valid data is missing around it, or the angle-point torque is at or below half of the lower limit. Measure again.

Torque & Angle mode

Torque & Angle counts rotation after the seating torque and lets you judge by angle (Live Angle) or by torque (Live Torque).

It needs an angle-output sensor such as TTAS. Rotation before the torque first reaches “Seating Torque” is not counted.

Torque & Angle Parameter Settings in four columns: Work Info, Target Torque, Target Angle with Mode and Judgement drop-downs, and Parameter Settings.
Mode and Judgement sit under Target Angle. Here Mode is Live Angle and Judgement is ≤. Switching Mode resets Judgement to its default.

“Mode” defaults to “Live Angle”. “Judgement” is “≥” or “≤” for Live Angle, and “±” or “≥” for Live Torque. “Angle Range” appears only in Live Torque.

ModeOK whenExample (90°, 50 N·m ±5%)
Live Angle “≥”Maximum valid angle is at or above the target.92.4° OK; 85.0° NOK
Live Angle “≤”Maximum valid angle is at or below the target.85.0° OK; 92.4° NOK
Live TorquePeak torque is within the limits; angle is saved, not judged.48.72 N·m with “±” OK

Choose the mode that matches the acceptance criterion in your work instruction.

The Torque & Angle work screen in Live Angle mode: Pending result, live torque 0.00 N·m, an Angle progress band, and a side card with Live Angle and Mode.
In Live Angle the progress band shows angle, not torque. The side card shows Live Angle and Mode, and the spec strip adds Target Angle and Angle Range.

Example: TTAS 180 N·m, seating torque 5 N·m, target 90°, “Live Angle” with “≥”. Apply force above 5 N·m while rotating and release at 92.4°: OK.

Batch jobs

A batch job chains work steps, each with its own mode, sensor and OK count, and runs them in order on the same part.

Editing jobs needs “Work management”. In the job list, “+” adds a job, “▶” runs it, “✎” edits it, and the trash can deletes it; records made with a deleted job are kept.

The Batch Job Parameter Settings screen: job name and On Completion at the top, step 1 expanded with Work Mode, Select sensor and target fields, and a Save Job button at the bottom.
Each step is a card and only one is expanded at a time. The collapsed header summarizes sensor, OK count and target torque; the count at the bottom left is the total steps.

“Name” is required (up to 64 characters). “On Completion” is “Return” (default) or “Work Cycle”. Each step sets a Work Mode, sensor, target values and “OK count per batch” (1 or more), plus multiplier fields. Steps can be moved, removed or duplicated with “Add Step”. After switching Work Mode or sensor, recheck targets and batch count.

Example: step 1 is Torque & Angle on a TTAS 180 N·m (50.00, 5%, angle 90, “Live Angle”, “≥”, OK count 2). Duplicate it as step 2, switch it to Torque Measurement with OK count 1, and save.

The batch work screen for step 1 of 2: receiver and sensor details at the left, Pending result and live torque in the centre, step and progress at the right, and a bar of steps along the bottom.
The bottom bar shows each step with its completed / required count. Check the sensor serial number at the left against the sensor expected for the current step.
  1. Tap “▶”. TMS prepares the receiver and sensor for step 1, then shows the job name, “Cycle Count”, “Current Step” and progress.
  2. Scan the part number once; all steps belong to that part.
  3. Only OK advances a step; NOK is saved but does not advance it.
  4. At the step’s OK count, TMS switches to the next step and the receiver follows that sensor’s channel. Make sure the next sensor is on.
  5. After the last step, “Batch Complete” shows for about 1 second, the part number clears and a new round starts at step 1.

“Return” starts a new run of the same job after about 1 second and restarts the cycle count at 1; “Work Cycle” continues in the same run and counts 1, 2, 3. Neither returns to the job list.

If the link drops, the screen shows “Disconnected” and keeps progress. If it stays on “Pending” after a step switch, or shows “RF link timed out”, stop applying force and check the next sensor’s power, serial number and channel. If that fails, re-detect the receiver, reselect the sensor and restart the job.

Records and export

Every measurement is saved automatically; Records and Export lets you search them, inspect the curve and export CSV or Excel.

Path: System Settings → Records and export (permission “Measurement records”; exporting also needs “Export CSV”). Set Start Date and End Date, “Work Mode” and “Result”, then tap the magnifier; the list shows 50 records per page.

The Records and export list: Start Date, End Date, Work Mode and Result filters, a green search button, a blue download button, and a table of records with Final Torque, Final Angle, Result and End Time columns.
After changing any filter, tap the green magnifier to refresh the list. OK rows are green and NOK rows red; Record Detail opens the curve.
The Record Detail screen of an NOK Torque Wrench record: a red result tile and fields for mode, final torque, limits and end time at the left, and a torque against time chart with limit lines at the right.
The limits are the ones saved with this measurement, so later parameter changes do not alter them. The chart header gives the data point count (30 here).

Details show result, part number, mode, end time, final torque and angle, and the saved limits. Tap once in the chart for a cursor with time, torque and angle; values between points are interpolated, for reading only.

  • Summary CSV: query first, tap the blue download arrow, check the record count, tap “Confirm CSV export”, then choose a folder and allow access. It covers all results of the last query, one row per record, without curve data.
  • Single record: in “Record Detail” tap “CSV” (one row per data point) or “Excel” (.xlsx with “Record Summary”, “Data Points” and “Torque Angle Chart” sheets and an editable chart).

Files are UTF-8 with BOM, so Excel opens them directly. The delimiter is a comma for seven languages (including English and Chinese) and a semicolon for the other nine. Column names, dates, numbers and torque unit follow the interface at export time. Excel cannot export above 1,048,575 points; use the complete CSV.

If export fails, check for an empty list, a missing permission, an unwritable folder or full storage. The manual notes that export and folder selection have not yet been tried on a real device in this version; if it still fails, report it and do not clear the app data.

Modbus TCP

TMS can act as a Modbus TCP server so a PLC or computer can read results and send a few commands.

Warning. Modbus TCP has no encryption and no account authentication. Use it only on a controlled factory LAN, never expose the port to the Internet, and set it to “Disabled” and save when unused.

Path: System Settings → Communication Settings (permission “System settings”). TMS is the server; the PLC is the client. On Android, only Modbus TCP is supported; Modbus RTU, Open Protocol and the capability index are Windows-only.

The Communication Settings screen with the Modbus TCP server enabled: TCP status Listening, local IP and port, TCP Port, Unit ID, read-only bind, client and idle values, and a Save and apply communication settings button.
After enabling and saving, check that TCP shows “Listening”, then give the Local IP and port to the PLC. Data addresses are 30001–30064 and control addresses 40001–40027.
  1. Put the device and PLC on the same LAN without client isolation.
  2. Set the server to “Enabled”. Defaults: “TCP Port” 1502, “Unit ID” 1; at most 4 clients connect.
  3. Tap “Save and apply communication settings”; confirm “Listening”.
  4. In the PLC, create a client with the Local IP, port and Unit ID.
  5. Read 30001–30002 with FC04: you should get 0x544D and 2. Then read 30009–30064.

A PLC can read live status and the latest completed result, not history: live and final torque and angle, limits, the judgement, batch counts, pulse count, completion time and sensor data. Check the validity bits first.

Commands use FC16 to write 20 registers at 40002–40021 in one request. They are: apply parameters, select a batch recipe, lock tool, unlock tool and reset batch. A write response only means the registers were written; read the reply status and error.

The manual’s Modbus tests used version 1.1.3, and the success case of “apply parameters” was not verified, so confirm commands in a test environment first. Test with no force applied.

Sensor fault records and alerts

TMS shows sensor faults as banners or dialogs during work and keeps a searchable history.

Path: System Settings → Sensor fault records. Set “Status” to All, Active or Resolved and tap “Query”; leave “Sensor” blank, because a serial number does not filter.

  • 0x01 Low battery (warning only): charge or replace the battery.
  • 0x02 Torque overload (work stopped): stop force, check whether the specification was exceeded, calibrate.
  • 0x04 Zero drift (work stopped): stop using it and calibrate.
  • 0x08 / 0x10 / 0x20 Hardware damage (work stopped): contact the supplier.
  • 0x40 5,000 cycles reached (warning only): arrange calibration.

A warning shows a yellow banner and you can continue. A stop-type error opens a “Sensor fault” dialog that blocks work: stop applying force and tap “Go to sensor pairing”; do not carry on just by reconnecting.

The low-battery warning appears at 10% or below for 2 consecutive seconds, or at once when the sensor reports it; measurement continues. The alert clears only after 20% or more is received for 5 seconds. A battery value of “—” means none received yet, not 0%.

Daily workflow, maintenance and troubleshooting

A short check before each shift and a fixed export routine keep records trustworthy.

  • Before a shift: check the login-screen version, receiver “Paired”, sensor serial number, battery and calibration, and that parameters match the work instruction. Measure a test piece once.
  • After a shift: stop force, confirm the last result is saved, export the shift’s records and check the file opens, note any problems, and charge the sensor.
  • Weekly: back up exported records and keep 1 GB free. Monthly: check “Sensor fault records” and the OTG and receiver contacts.
  • At each calibration interval, or the 5,000-cycle prompt: calibrate the sensor.

Common problems

SymptomCauseFix
“Receiver not detected”; light on but no readingPoor OTG contact, sensor off, channel mismatch or not paired.Re-plug, tap “Detect wireless receiver again”, check sensor and channel.
“RF link timed out”Sensor off or too far.Stop force; switch the sensor on; move it closer.
“Failed to load or save settings”Field out of range, missing permission or no sensor.Correct fields; check permissions.
“Conditions not met”Seating torque not reached or target angle not passed.Check conditions; measure again.
Export fails or PLC cannot readNo data, permission, folder; or server off, IP, port or Unit ID mismatch.Query first, check permissions; confirm “Listening” and matching values.

Before you contact the supplier

Prepare the TMS version and build date; the Android model and version; work mode, sensor model, serial number and channel; the time, your steps and the full error text. Include no passwords.

Questions about TMS RF?

Tell us the transducer or controller model, the operating system, the TMS RF version and what you are trying to do. A product engineer will answer directly.

This website uses cookies to ensure it works properly and to help us understand how visitors use the site. Cookies are small text files stored on your device. By using this website, you consent to our use of cookies.