STA (RF version)-Torque & Angle Control

STA (RF version)-Torque & Angle Control

What are required

ZIPPTORK 020 1 System Architecture

ZIPPTORK 020 2

Procedures

  1. Insert Dongle into Notebook or Tablet.
  2. Open the TMS software.
  3. Set Dongle port.
  4. Enter the STA mode and then press the “Setup” button to enter the “Setup” page.
  5. Select the combination code.
  6. Please follow the combination shown in the tool combination code to complete the tool combination (headset with STA and interchangeable head torque wrench) in order.
  7. Turn on the STA transducer power.
  8. Select the STA transducer you want to use (the same tool combination setting is required).
  9. Select the working mode <Torque + Angle>.
  10. Set the inspection conditions and accuracy.
  11. Return to the work page.
  12. Set the initial target torque.
  13. Set the final target torque.
  14. Set the target angle.
  15. Start bolting.
  16. Release the STA after bolting to the target torque prompted by the system.
  17. Start bolting again and release STA after reaching the target angle.
  18. QC judgment.
  19. The system completes the work record (operator ID, date & time, target torque, actual torque, QC result and tool combination code).