STA (RF version) – Torque Control
What is required
System
Architecture

Procedures
- Insert the Dongle into the Notebook or Tablet.
- Open the TMS software.
- Set the Dongle port.
- Enter STA mode, then press the “Setup” button to open the “Setup” page.
- Select the combination code.
- Please follow the combination shown in the tool combination code to complete the assembly (head with STA and interchangeable head wrench) in the order shown.
- Turn on the STA transducer power.
- Select the STA transducer you want to use (should match the tool combination setting).
- Select the working mode <torque>.
- Set the inspection conditions and accuracy.
- Return to the work page.
- Set the final target torque.
- Start bolting.
- Release the STA after bolting to the target torque prompted by the system.
- QC judgment.
- System complete on work record (operator ID, date & time, target torque, actual torque, accuracy, and tool combination code).